The standard CD V-700 measures gamma radiation up to 50 milliroentgens per hour over three scales.
It uses a Geiger-Müller tube to detect moderate and high energy beta radiation, and gamma radiation
down to low energies. The probe operates at 900 volts which is essentially the center of a plateau
extending from about 850 volts to 920 volts. The probe has a beta shield that can twist to open or close.
The Geiger Mueller tubes are halogen quenched, and mounted in a probe connected to a 36" cable.
Instrument accuracy on any of its three ranges is within ± 10% of the true dose rate from Cobalt 60 gamma
radiation. This accuracy is maintained throughout a temperature range of -20° F to +125° F, and
 at altitudes from sea level to 25,000 feet.
The CD V-700 series of radiological survey meters use a meter for visual indication and a 4000 ohm
headset for audible detection of activity.
Battery life is 100 hours of continuous use. This is based on the carbon/zinc batteries of the early
1960's, newer alkaline batteries should do much better.


Government cost in 1969: $19.25
Government Procurement - Fiscal Year 1955 - 1985 452,558


Inside View
The Victoreen Instrument Co.
CD V-700 Model 2

Uses 2 "D" size 1 ½ volt & 3 "B" size 45 volt batteries.
This unit has an all aluminum top and bottom case.
Battery corrosion courtesy of original owners.
Also Known As : Vico 661



Chatham CD V-700 Model 3
Inside View
 Chatham Electronics
CD V-700 Model 3

Uses 2 "D" size 1 ½ volt & 3 "B" size 45 volt batteries.
This unit has a cast aluminum top and bottom with schematics inside the case.


Insid a Universal Atomics CD V-700 Model 4
Inside View
Universal Atomics
CD V-700 Model 4

Uses 5 "D" size 1 ½ volt batteries.
This unit has a plastic top and bottom with schematics on the back of the battery holder.
Unit came with a Anton Electronics Labs 114/6993 Letter "F" Geiger-Müller tube.
See the commercial version of this model here.
The same instruction manual is used for both the Civil Defense and commercial versions.


Anton CD V-700 Model 5
Inside View
 Anton Electronic Labs. Inc.
CD V-700 Model 5

Uses 5 "D" size 1 ½ volt batteries.
This unit has a all aluminum top and bottom with schematics inside the case.


Victoreen CD V-700 Model 6B
Inside View
The Victoreen Instrument Co.
CD V-700 Model 6B

Uses 4 "D" size 1 ½ volt batteries.
This unit has a cast aluminum top and steel bottom with schematics inside the case.


Lionel CD V-700 Model 6b

Inside View
Lionel Electronic Laboratories
CD V-700 Model 6b

Uses 2 "D" size 1 ½ volt batteries.
This unit has a cast aluminum top and steel bottom with schematics inside the case.



My Complete Collection of CD V-700 Geiger Counters



Nuclear Research Corporation
FCDA Item # CD-V-700


NRC Model SM-5A
Serial Number: 62

This meter is now part of a different collection
and can now be seen at this link....
http://www.orau.org/ptp/collection/
civildefense/nrcsm5a.htm







The Victoreen Instrument Co.
 CD V-700 Model 2

Serial Number: 2081
Note this has a "FCDA" item number.

This sure looks a lot like a
Nuclear Measurements GS-3



International Pump And
Machine Works, Inc.
 CD V-700 Model 3
 
  Serial Number: 15724      
Note this has a "FCDA" item number.
   

See special Geiger-Müller tube picture below.
Click picture to go to the
CD V-700 Model 3 Page. 



International Pump And Machine Worksl CD V-700 Model 3  
 



Chatham Electronics
 CD V-700 Model 3
 
  Serial Number: 5132      
Note this has a "FCDA" item number.


See special Geiger-Müller tube picture below.
Click picture to go to the
CD V-700 Model 3 Page.




Universal Atomics
 CD V-700 Model 4

 Serial Number: Removed
Plastic Top & Case
Note this has a "FCDA" item number.

Universal Atomics CD V-700 Model 4
Anton CD V-700 Model 5




Anton Electronics Labs. Inc.
 CD V-700 Model 5

Serial Number: 22205
½ Inch smaller in width and length than
the CD V-700 Model 6 series meters
.




Anton Electronics Labs. Inc.
 CD V-700 Model 6

Serial Number: 22556  
Anton CD V-700 Model 6


Lionel Electronic Laboratories
 CD V-700 Model 6

Serial Number: 201253

This is a model from 1960 when Anton Electronics Labs. became Lionel Electronic Laboratories. It has the Anton check source sticker on the side. This model uses 5 "D" cells like the Anton instead of the
2 "D" cells like the Lionel  model 6B.





The Victoreen Instrument Co.
 CD V-700 Model 6

Serial Number: 4491

Victoreen CD V-700 Model 6A



The Victoreen Instrument Co.
 CD V-700 Model 6A

Serial Number: 52692



The Victoreen Instrument Co.
 CD V-700 Model 6B
 Serial Number: 65256  
Note the ruggedized meter lens on this one, it is the only difference between these two Victoreen CD V-700 Model 6B's.
The ruggedized lens provided more EMP protection than the original meter face.

Victoreen CD V-700 Model 6B
Victoreen CD V-600 Model 6B



The Victoreen Instrument Co.
 CD V-700 Model 6B
Serial Number: 65971
Note the original meter lens on this one, it is the only difference between these two Victoreen CD V-700 Model 6B's




Electro-Neutronics Inc.
 CD V-700 Model 6b

Serial Number: 16046
Electro-Neutronics CD V-700 Model 6b
Lionel CD V-700 Model 6b



Lionel Electronic Laboratories
 CD V-700 Model 6b

Serial Number: 77557




The Victoreen Instrument Co.
 CD V-700 Model 6A

Extended Range Model  
Serial Number: 33203
Special extended range model page can be seen by clicking the pictures.






The Victoreen Instrument Co.
 CD V-700 Model 6B

Extended Range Model  
Serial Number: 125317
Special extended range model page can be seen by clicking the pictures.




Geiger Mueller Tubes
Standard "6993" Geiger-Müller tube on left. Tube from Chatham CD V-700 Model 3 on right.
Tube on left is a Anton 114 / 6993                         Tube on right is a Amperex 85NB / 6980


"6993" GM Tubes
Various "6993" Geiger-Müller tubes.
Left to Right:
Anton Electronics Labs     114 / 6993 Letter "H"
EON Corporation     Type 6993
Anton Electronics Labs     114 / 6993
The Victoreen Instrument Corp.     6993
The Victoreen Instrument Corp.     OCDD-103
Lionel Electronics Labs.     6993 / 114



6993 Geiger-Müller Tube Dimensions
From the Nucleonics Corporation of America CD V-457 Model 2 manual.


Exploded view of a Geiger-Mueller tube
Page from the Anton CD V-700 Model 6 manual showing Geiger-Müller tube & probe.
This probe &  tube assembly is typical of
most CD V-700 survey meters.

See picture above for Chatham CD V-700 Model 3 
Geiger-Müller tube.
See picture below for Chatham CD V-700 Model 3 probe.



Probe Tubes
 CD V-700 probes with beta shields open.
 
Left To Right:
Chatham Electronics CD V-700 Model 3
Universal Atomics CD V-700 Model 4
Anton Electronics Labs. Inc. CD V-700 Model 5
The Victoreen Instrument Co. CD V-700 Model 6A

British Military
Calculators
Canadian Military
Civil Defense
Commercial
Downloads
Canada CD Pamphlets
European Military
Civil Defense Museum
Home
Fallout Shelter Plans
Russian Military
United States Military
United States Navy
Simulators / Trainers
Visitors Gallery